Register of Confined SpacesAny below-ground pit or conduit should be taken, prima facie, to be a confined space. Part A: Confined Spaces under the Control of Facilities and ServicesNumber* | Description | Location | Potential hazards** | Entries per year | Signage, Entry permits | Contact Person | | a-bbb-cc | | | | | Sgn | EP | Control Entry/Exit | | | 3-039-01 | service ducts within basement | Psychology/Physics | 1,2,4,8,10,16 | | | | | Facilities and Services | | 1-000-02 | pit (closest to building 82) | Between Sullivans Creek and bike path | 2,3,6,7,10,14 | | | | | Facilities and Services | | 4-000-01 | pit (closest to building 16A) | Sullivan's Creek, footbridge, east | 2,3,6,7,10,14 | 2 |  |  |  | Facilities and Services | | 3-035-01 | silt/neutralising pits | RSC | 1,2,3,6,7, 10,11,14 | 2 | |  |  | Facilities and Services | 2-046-04 | silt/neutralising pits | RSBS rear of EM Unit | 1,2,3,6,7, 10,11,14 | 2 | |  |  | Facilities and Services | | 2-046-05 | silt/neutralising pits | RSBS front of building | 1,2,3,6,7, 10,11,14 | 2 | |  |  | Facilities and Services | | 2-046-06 | silt/neutralising pits | RSBS Japanese garden | 1,2,3,6,7, 10,11,14 | | |  |  | Facilities and Services | | 2-046-07 | silt/neutralising pits | RSBS adjacent to Japanese garden | 1,2,3,6,7, 10,11,14 | | |  |  | Facilities and Services | | 1-061-02 | silt/neutralising pits | RSES adjacent J3 plant room | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 1-061-03 | silt/neutralising pits | RSES adjacent to J7 bike rack | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 1-061-04 | silt/neutralising pits | RSES rear courtyard J1 | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 1-061-05 | silt/neutralising pits | RSES ohb b block adjacent to ramp | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 4-009-01 | silt/neutralising pits | HC Coombs loading dock | 1,2,3,6,7,10,11,14 | 1 | | | | | | 1-058-07 | silt/neutralising pits | RSPhysSE | 1,2,3,6,7, 10,11,14 | 1 | | | | Facilities and Services | | 2-041-01 | silt/neutralising pits | BaMBi | 1,2,3,6,7, 10,11,14 | 1 |  |  |  | Facilities and Services | | 2-041-02 | silt/neutralising pits | BaMBi | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 2-044-01 | silt/neutralising pits | BoZo | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 2-044-02 | silt/neutralising pits | BoZo | 1,2,3,6,7, 10,11,14 | 2 | |  | | Facilities and Services | | 3-033-01 | silt/neutralising pits | Chemistry | 1,2,3,6,7, 10,11,14 | 1 | |  | | Facilities and Services | | 2-042-01 | silt/neutralising pits | Frank Fenner Building | 1,2,3,6,7, 10,11,14 | 1 |  |  | | Facilities and Services | | 3-031-01 | silt/neutralising pits | FEIT | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 2-048-01 | silt/neutralising pits | Forestry | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 2-047-01 | silt/neutralising pits | Geology | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services | | 2-085-01 | silt/neutralising pits | Field Services | 1,2,3,6,7,10,11,14 | 1 | | | | | | 3-038-01 | silt/neutralising pits | Physics | 1,2,3,6,7, 10,11,14 | | |  |  | Facilities and Services | | 2-045-01 | silt/neutralising pits | University Maintenance | 1,2,3,6,7, 10,11,14 | 2 | |  |  | Facilities and Services | | 1-124-01 | silt/neutralising pits | Innovations | 1,2,3,6,7, 10,11,14 | 1 | |  |  | Facilities and Services |
Part B: Confined Spaces under the Control of a Budget Unit - General SpacesBudget Unit | Number* | Description | Location | Potential hazards** | Entries per year | Signage, Entry permits | Contact Person | | | a-bbb-cc | | | | | Sgn | EP | Control Entry/Exit | | | JCSMR | | | | | | | | | | | | 1-054-01 | liquid nitrogen room E2148 | JCSMR | 1,2 | many |  | Workplace control procedure |  | | | | 1-054-02 | liquid nitrogen room E2149 | JCSMR | 1,2 | many |  | Workplace control procedure |  | | | | 1-131-01 | subfloor access below bldg 131 main stairs | JCSMR
| 1, 4, 8, 20 | |  | |  | School Technical Service Head | | | 1-054-05 | old stores tunnel | JCSMR Spine Level 1 | 1, 2, 14 | |  | |  | School Technical Service Head | | RSAA | | | | | | | | | | | | 5-000-01 | Coude Room, 74" telescope | Mount Stromlo | 8,7,14 | | | | | | | 5-000-02 | Water Storage Tank | Siding Spring | 7,8,13,14 | | | | | | | | 5-000-03 | Water Storage Tower | Siding Spring | 1,2,3,7,8,19,23 | | | | | | | | 5-000-04 | Faulkes Telescope Basement | Siding Spring | 1,4,6,7,8,9,10,19,23 | | | | | | | | 5-000-05 | Timor Dam | Siding Spring | 1,2,7,8,10,14,20,23 | 1 | | | | | | | 5-000-06 | Mopra Property | Siding Spring | 1,2,7,8,10,14,20,23 | 1 | | | | | | | 5-000-07 | 4WD Mountain Track | Siding Spring | 1,2,7,8,10,14,20,23 | 1 | | | | | | | 5-000-08 | 4WD Mountain Track | Siding Spring | 1,2,7,8,10,14,20,23 | 1 | | | | | | RSBS | | | | | | | | | | | | 2-046-01 | fresh air intake | East Wing | 4,7,8,9 | 1 | | | | | | | 2-046-02 | service ducts within basement | RSBS | 1,2,3,11 | | | | | | | | 2-046-03 | fresh air intake | West Wing | 4,7,8,9 | 1 | | | | | | | 2-046-08 | silo | | 1,2,4,6,7,8,9,10,19,22 | | | | | | | RSC | | | | | | | | | | | | 3-035-02 | service ducts within basement | RSC | 1,2,3,11 | |  |  |  | | | RSES | | | | | | | | | | | | 1-061-01 | ceiling space | Jaeger 2 | 4,7,10,12,20 | |  |  |  | Eric Ward | | | 1-061-06 | Service duct basement | Jaeger 1 | 1,2,3,4,7,10,20 | | | | | Eric Ward | | | 1-061-07 | Service tunnel below workshop | Jaeger 6 | 1,4,13,19,20 | | | | | Eric Ward | | RSPhysSE | | | | | | | | | | | | 1-058-03 | building space foundation cavity | Cockcroft building stairwell level 2 | 1,7,8,12 | 4 | | | | Kevin Lonsdale | | | 1-058-04 | building space service duct | Carver central stairwell level 3 | 4,7,10,20 | | | | | Kevin Lonsdale | | | 1-058-05 | building space foundation cavity | front basement Oliphant Northern retaining wall | 1, 2, 8, 10, 15, 23 | | | | | | | | 1-058-06 | stairway sub floor | Oliphant main entry stairs | 4, 8, 20, 23 | | | | | | | | 1-058-08 | sub floor access adjacent plant room | Le-Couteur Building | 1, 2, 4, 8, 12, 20 | | | | | | | | 1-058-09 | sub floor access Northern side only | Le-Couteur Building | 1, 2, 4, 8, 12, 20 | | | | | | | Phenomics Facility | 1-117-01 | vacuum bin, sludge | loading dock 1.81 | 1, 2, 3, 15, 20, 21 | 2 | | | | | University House | | | | | | | | | | | | 1-001-01 | basement tunnel | University House | 2,4,11 | many |  |  |  | |
Part C: Confined Spaces under the Control of a Budget Unit -Research InstallationsBudget Unit | Number* | Description | Location | Potential hazards** | Entries per year | Signage, Entry permits | Contact Person | | | a-bbb-cc | | | | | - Sgn
| EP | Control Entry/Exit | | | RSPhysSE | | | | | | | | | | | | 1-058-01 | 14UD accelerator tank | Cockcroft Building | 2,10 | 2 | | | | Dr D Weisser | | | 1-058-02 | Heliac | Cockcroft Building | 2,7,9,10, 19,20 | | | | | Dr B Blackwell Mr J Wach |
* a: 1= zone 1, 2 = zone 2, 3 = zone 3, 4 = zone 4, 5 = non-Acton campus bbb: ANU building number ** Potential Hazards Legend | 1. low oxygen | 9. mechanical motion | 17. non-ionizing raditaion | | 2. asphyxiants | 10. eletric shock/electrocution | 18. noisy environment | | 3. poisoning (inhalation/skin) | 11. fire/explosion | 19. manual handling | | 4. head impact | 12. heat stress | 20. constrained movement | | 5. eye impact | 13. cold stress | 21. entrapment | | 6. falling objects | 14. drowning | 22. engulfment | | 7. fall from heights | 15. burial beneath solids | 23. other hazards | | 8. slips, trips or falls | 16. ionizing radiation | |
|